Oil Collection Results:

Adsorption capacity depends on the temperature and thickness of the oil.

E.P.S. Oil Adsorbent has been tested in Australia by SGS Leeder Consulting based on ASTM test standard F726-12.

Wet Conditions:

Medium (g/g)

Adsorption capacity for 15 Minutes

Adsorption capacity for 24 hours

Australian Reference Kuwait Oil

5.4

6.6

IFO 180

8.8

10.3

IFO 380

8

8.9

Fuel Oil at 30C

9.32

N.A.

Hydraulic Oil at 30C

5.34

N.A.

Canola Oil

4.31

N.A.

Diesel at 30C

2.46

N.A.

Water

0.79

N.A.

Dry Conditions:

Medium (g/g)

Adsorption capacity for 15 Minutes

Adsorption capacity for 24 hours

Australian Reference Kuwait Oil

4.5

5.8

IFO 180

6.2

7

IFO 380

5.7

6.3